Circuit/System Testing
- Ignition/Vehicle Off
- Disconnect the electrical connector: X2 K33 HVAC Control Module
- Connect a test lamp between the test points: Control terminal 17 X2 & Ground
- Engine Running
- Verify the test lamp does not turn On.
- If the test lamp turns On
- Ignition/Vehicle Off
- Disconnect the electrical connector: X1 K9 Body Control Module
- Ignition On/Vehicle In Service Mode
- Test for less than 1 V between the test points: Control terminal 17 X2 & Ground
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V, replace the component: K9 Body Control Module
- If the test lamp does not turn On
- Connect a 3 A fused jumper wire between the test points: Signal circuit terminal 15 X2 & Ground
- Verify the test lamp turns On.
- If the test lamp does not turn On
- Ignition/Vehicle Off
- Disconnect the electrical connector: X1 K9 Body Control Module
- Test for infinite resistance between the test points: Control terminal 17 X2 @ Control module harness & Ground
- If less than infinite resistance, repair the short to ground on the circuit.
- Ignition/Vehicle Off
- Test for less than 2 Ω between the test points: Control terminal 17 X2 @ Component harness & Terminal 23 X1 @ Control module harness
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω replace the component: K9 Body Control Module
- Replace the component: K33 HVAC Control Module