Removal Procedure
- Remove Air Cleaner Resonator-Air Cleaner Outlet Duct to Engine - Air Cleaner Resonator Replacement (Air Cleaner Outlet Duct to Engine)
- Remove the drive belt. Drive Belt Replacement - Accessory
- Disconnect the engine wiring harness connector (1), oil pump flow control valve connector (2), camshaft position actuator solenoid connector (3), and camshaft position sensor connector (4).
- Remove the camshaft position sensor bracket fasteners (1) from the engine block.
- Reposition the camshaft position sensor bracket and sensor wiring harness (1).
- Remove the camshaft position sensor (1) from the engine front cover.
NOTE:
If reinstalling the original camshaft position sensor, inspect the seal (2) for wear and replace as needed. Always install the NEW seal supplied with the new camshaft position sensor.