Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the tilt/telescope switch.
- Ignition ON, verify a test lamp illuminates between the B+ circuit terminal 1 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Verify the scan tool tilt switch and telescope switch parameters are Inactive.
- If not the specified value, test the signal circuits listed below for a short to voltage. If the circuit tests normal, replace the MSM.
- Tilt Up Switch terminal 2
- Tilt Down Switch terminal 6
- Telescope Forward Switch terminal 3
- Telescope Rearward Switch terminal 5
- Install a 3A fused jumper wire between the signal circuits listed below and the B+ circuit terminal 1 . Verify the scan tool tilt switch and telescope switch parameters are Active.
- Tilt Up Switch terminal 2
- Tilt Down Switch terminal 6
- Telescope Forward Switch terminal 3
- Telescope Rearward Switch terminal 5
- If not the specified value, test the appropriate signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the MSM.
- If all circuit test normal, test or replace the tilt/telescope switch.