| 2 |
Ignition Coils Procedure
- Disconnect the electrical wiring harness connectors from the ignition coils and remove coils as necessary.
- Apply a thin coating of dielectric grease to the inside of the ignition coil rubber boot, up to a depth of 15 mm from the end of the boot. Refer to Adhesives, Fluids, Lubricants and Sealers
.
NOTE:
Inspect the inside of the ignition coil rubber boot for a thin, even coat of grease. If there is no grease present or additional grease is necessary, complete the following procedure.
- Remove any excess grease from around the end of the boot and ensure there is not an excessive amount within the boot.
|