Circuit/System Testing
DTC B023A
- Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the components listed below. It may take up to 2 min for all vehicle systems to power down.
- M37 Mode Door Actuator
- M46 Air Recirculation Door Actuator
- M6 Air Temperature Door Actuator
- Disconnect the harness connector at the K33 HVAC Control Module.
- Test for infinite resistance between the K33 HVAC Control Module 12 V reference circuit terminal 15 and ground.
- If less than infinite resistance
Repair the short to ground on the circuit.
- If infinite resistance
- If less than infinite resistance
- Ignition ON.
- Test for less than 1 V between the K33 HVAC Control Module 12 V reference circuit terminal 15 and ground.
- If 1 V or greater
Repair the short to voltage on the circuit.
- If less than 1 V
- If 1 V or greater
- Connect the harness connector at the K33 HVAC Control Module, ignition ON.
- Clear all DTCs.
- Verify DTC B023A is not set.
- If the DTC is set.
Replace the K33 HVAC Control Module.
- If the DTC is not set.
- If the DTC is set.
- Verify DTC B023A does not set after connecting each of the components listed below one at a time and operating them through their full range.
- M37 Mode Door Actuator
- M46 Air Recirculation Door Actuator
- M6 Air Temperature Door Actuator
- If the DTC sets after connecting one of the components
Replace the component that was connected immediately before the DTC set.
- If the DTC does not set
- All OK.
DTC B0223, B022A, B0233, or B0408
- Ignition OFF, disconnect the harness connector at the appropriate door actuator, ignition ON.
- Verify a test lamp flashes when connected between the 12 V reference circuit terminal 2 and ground.
- If the test lamp does not flash
- Ignition OFF, remove the test lamp and disconnect the harness connector at the K33 HVAC Control Module.
- Test for less than 2 Ω in the 12 V reference circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K33 HVAC Control Module.
- If the test lamp flashes
- Connect a test lamp between each control circuit listed below and B+.
- Control Circuit - terminal 1
- Control Circuit - terminal 3
- Control Circuit - terminal 4
- Control Circuit - terminal 6
- Command the appropriate door actuator in both directions.
- Verify the test lamp turns ON and then OFF during at least one of the directional commands.
- If the test lamp is always ON
- Ignition OFF, remove the test lamp and disconnect the harness connector at the K33 HVAC Control Module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K33 HVAC Control Module.
- If the test lamp is always OFF
- Ignition OFF, remove the test lamp and disconnect the harness connector at the K33 HVAC Control Module, ignition ON.
- Test for less than 1 V between the control circuit and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V
- Ignition OFF
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater, repair the open/high resistance is the circuit.
- If less than 2 Ω, replace the K33 HVAC Control Module.
- If the test lamp turns ON and then OFF
- Replace the door actuator.