Circuit/System Testing
- Verify no other battery charger DTCs are set.
- If any other battery charger DTCs are set
Refer to Diagnostic Trouble Code (DTC) List - Vehicle .
- If no other battery charger DTCs are set
- If any other battery charger DTCs are set
- Vehicle OFF. Wait 2 minutes for C1 Battery voltage to stabilize.
- Test for 12.4-12.8 V between the C1 Battery terminals.
- If not within the specified range
Refer to Battery Inspection/Test .
- If within the specified range
- If not within the specified range
- Vehicle ON, accessories OFF.
- Test the C1 Battery for at least 1 V greater than the voltage measured in step 3 but less than 15 V.
- If not within the specified range
Refer to DC Power Conversion Test .
- If within the specified range
- If not within the specified range
- Replace the T18 Battery Charger.