K33 HVAC Control Module X1
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | 13575845 | J-35616-64B (L-BU) | J-38125-215A | SAIT-A03T-M064 | 14 | P | P |
K33 HVAC Control Module X1
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1-3 | - | - | - | Not Occupied | - | - |
| 4 | 0.35 | D-GN | 734 | Inside Air Temperature Sensor Signal | I | CJ2 |
| 5 | 0.35 | GY | 1548 | Passenger Sunload Sensor Signal | I | CJ2 |
| 6-7 | - | - | - | Not Occupied | - | - |
| 8 | 0.5 0.5 |
PK PU/WH |
2145 760 |
Air Temperature Switch Signal - Right Auxiliary Blower Motor Speed Control |
I | C67 CJ2 without ULD |
| 9 | 0.5 | OG | 2615 | Auxiliary Mode Door Control | I | without ULD |
| 10 | 0.5 | YE | 2214 | Auxiliary Air Temperature Door Control | I | without ULD |
| 11-14 | - | - | - | Not Occupied | - | - |
| 15 | 0.35 | L-BU/BK | 590 | Driver Sunload Sensor Signal | I | CJ2 |
| 16 | 0.35 | TN | 516 | Upper Left Air Temperature Sensor Signal | I | CJ2 |
| 17 | 0.35 | TN | 517 | Upper Right Air Temperature Sensor Signal | I | CJ2 |
| 18 | 0.5 0.5 |
GY PK |
2599 2145 |
Auxiliary Mode Door Control Air Temperature Switch Signal - Right |
I | C67 CJ2 |
| 19 | 0.5 0.5 |
PU/WH GY |
760 2599 |
Auxiliary Blower Motor Speed Control Auxiliary Mode Door Control |
I | C67 without ULD CJ2 |
| 20 | - | - | - | Not Occupied | - | - |