Circuit/System Testing
- Ignition OFF, disconnect the KR70 auxiliary power relay.
- Test for less than 10 Ω between the ground circuit terminal 86 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Verify that a test lamp does not illuminate between the control circuit terminal 30 and ground.
- If the test lamp illuminates, test the control circuit for a short to voltage.
- Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 85 and ground.
- If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K9 BCM.
- Verify that a test lamp illuminates between the B+ circuit terminal 87 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 30 for a short to ground.
- Disconnect the harness connector at the inoperative X80 accessory power receptacle or E32 cigarette lighter receptacle.
- Test for less than 10 Ω between the ground circuit terminal C and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect the harness connector at the X80 accessory power receptacle or E32 cigarette lighter receptacle.
- Connect a 20 A fused jumper wire between the KR70 auxiliary power relay B+ circuit terminal 87 and the control circuit terminal 30. Verify the 12 V DC accessory has power.
- If the 12 V DC does not have power, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the X80 accessory power receptacle or E32 cigarette lighter receptacle.
- If all circuits test normal, test or replace the KR70 auxiliary power relay.