Circuit/System Testing
- Ignition ON, command the instrument cluster, All Indicators test ON and OFF with a scan tool. The Stabilitrak indicator should turn ON and OFF when changing between the commanded states.
- If the indicator does not turn ON and OFF, replace the P16 Instrument Cluster.
- Replace the K17 EBCM.