Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the DIC switch assembly.
- Ignition OFF, test for less than 1 ohm between the low reference circuit terminal F and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance.
- Ignition ON, verify that all scan tool DIC Switch parameters are Inactive, Released or Off.
- If any are not Inactive, Released or Off, test the signal circuit terminals listed below for a short to ground. If the circuit tests normal, replace the IPC.
- Gauges switch signal terminal H
- Trip switch signal terminal J
- Options switch signal terminal K
- Reset switch signal terminal G
- Fuel switch signal terminal C
- Ignition ON, install a 3A fused jumper wire between the signal circuit terminals listed below and the low reference circuit terminal F. Verify that all scan tool DIC switch parameters are Active, Depressed or On.
- Gauges switch signal terminal H
- Trip switch signal terminal J
- Options switch signal terminal K
- Reset switch signal terminal G
- Fuel switch signal terminal C
- If any DIC switch parameters are not Active, Depressed or On, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC.
- If all circuits test normal, test or replace the DIC switch.