Removal Procedure
- Remove the auxiliary power outlet fuse from the fuse block.
- For the receptacle mounted in the cover, remove the front floor console cover. Refer to Front Floor Console Front Cover Replacement (Without UMQ) or Front Floor Console Front Cover Replacement (With UMQ) .
- Remove the receptacle:
- Look into the receptacle. There are two 3 mm (0.11 in) tab windows 12 mm (0.47 in) from the front of the receptacle. The J 42059 pushes the plastic latches from these tab windows and the receptacle can be pulled straight out. See Special Tools .
- Place one side of the "T" portion of the J 42059 into the tab window. The J 42059 will not fit straight into the receptacle. Angle the J 42059 slightly for insertion into the receptacle. See Special Tools .
- Insert the other side of the "T" into the opposite tab window.
You must move the J 42059 handle toward horizontal to engage the other tab window. See Special Tools .
- Use the J 42059 to pull the receptacle straight out. See Special Tools .
- If J 42059
tool fails to release the lighter socket from the retainer, perform the following alternate method:. See Special Tools .
- Insert a small grinding tool with a cutoff wheel into the socket.
- Remove the plastic latches in the 3 mm (0.11 in) square windows.
- Use the J 42059 as directed above to remove the socket. See Special Tools .