Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the generator.
- Engine Running, command the Gernerator L-Teriminal Command OFF with a scan tool. Test for less than 1 V between the generator turn on signal circuit terminal 1 and ground.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Engine Running, command the Generator L-Terminal Command ON with a scan tool. Test for greater than 3.5 V between the signal circuit terminal 1 and ground.
- If less than the specified range, test the signal circuit for a short to ground, an open or a high resistance. If the circuit tests normal, replace the ECM.
- If the circuit tests normal, test or replace the generator.