LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2010 >> Traverse LS, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 7 (Lighting Systems) >> Repair Instructions >> Brake Pedal Position Sensor Calibration >> Calibration Procedure

Calibration Procedure

WARNING: This page is about a different car, the 2009 Saturn Outlook, 2009 GMC Acadia, 2009 Chevrolet Traverse, and 2009 Buick Enclave. However, it is still accessible from the selected car via links, so may be relevant.
  1. Apply the parking brake.
  2. Place the transmission in the PARK position.
  3. Install a scan tool.
  4. Clear all BCM DTCs before proceeding.
  5. Navigate to the Vehicle Control Systems menu.
  6. Select Module Setup menu item.
  7. Select BCM menu item.
  8. Select the BPP Sensor Calibration procedure and follow the directions displayed on the screen.