Home >> Chevrolet >> 2010 >> Traverse LS, AWD >> Repair and Diagnosis (Single Page) >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Description and Operation >> Charging System Description and Operation >> Electrical Power Management (EPM) Overview >> Charging System Components >> Battery Current Sensor

Battery Current Sensor

The battery current sensor is attached to the positive battery cable, and is not serviceable. If the current sensor requires replacement the positive battery cable must be replaced. The battery current sensor is a 3-wire hall effect current sensor. The battery current sensor monitors the battery current. It directly inputs to the BCM. It creates a 5-volt pulse width modulation (PWM) signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is between 5-95 percent. Between 0-5 percent and 95-100 percent are for diagnostic purposes.