Temperature Versus Resistance (Reductant Tank Temperature Sensor)
Reduction Tank Temperature Sensor
| °C | °F | OHMS |
|---|---|---|
| Resistance Values are ± 3% Temperature Values are ± 5% |
||
| -5 | 23 | 42,315 |
| 0 | 32 | 32,650 |
| 5 | 41 | 25,388 |
| 10 | 50 | 19,900 |
| 15 | 59 | 15,708 |
| 20 | 68 | 12,490 |
| 25 | 77 | 10,000 |
| 30 | 86 | 8.057 |
| 35 | 95 | 6,531 |
| 40 | 104 | 5,327 |
| 45 | 113 | 4,369 |
| 50 | 122 | 3,603 |
| 55 | 131 | 2,986 |
| 60 | 140 | 2,488 |
| 65 | 149 | 2,083 |
| 70 | 158 | 1,752 |
| 75 | 167 | 1,481 |