Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the information center telltale assembly.
- Ignition ON, verify that a test lamp illuminates between the voltage control circuit terminal A and ground.
- If the test lamp does not illuminate, test the voltage control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the object alarm module.
- Connect a test lamp between the voltage control circuit terminal A and the appropriate LED control circuit:
- Left amber LED - terminal B
- Center amber LED - terminal C
- Red LED - terminal D
- Command the appropriate LED ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the object alarm module.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the object alarm module.
- If all circuits test normal, test or replace the information center telltale assembly.