Circuit/System Testing
- Ignition OFF, remove the fuse that supplies voltage to terminal X2-5 of the ECM. Verify the fuse is OK.
- If the fuse is open, test the ignition voltage circuit between the open fuse and the ECM for an intermittent short to ground.
NOTE: This DTC will only set if the fuse is open and the circuits are not grounded. The ignition voltage circuits must be tested thoroughly for an intermittent short to ground. - Install the fuse.
- Disconnect the harness connectors of the ECM.
- Ignition ON, load test for B+ on the ignition circuit terminal X2-5 of the ECM connector.
- If less than B+, repair the ignition circuit for an open/high resistance.