Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the information center telltale assembly.
- Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal A and ground.
- If the test lamp does not illuminate, test the B+ circuit terminal for a short to ground or an open/high resistance. If the circuit tests normal, replace the object alarm module.
- Connect a test lamp between the B+ circuit terminal A and the appropriate control circuit listed below:
- Amber 1 LED - terminal B
- Amber 2 LED - terminal C
- Red LED - terminal D
- Command the appropriate LED ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the object alarm module.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the object alarm module.