Circuit/System Testing

WARNING: This page is about a different variant/trim than selected.
  1. Disconnect the MGU X2 and the SGCM X2 connectors. Refer to Generator with Starter Replacement  and Generator Control Module Replacement .
  2. Test the circuits in the SGCM to MGU Terminal Reference Table as indicated below. Also test these circuits for short to ground.
    • If any of the circuits are not within specification, repair the open/high resistance or short to ground.
  3. Reconnect MGU connector X2.
  4. Test the circuits in the MGU to SGCM Specification Table to ground as indicated below.
    • If all circuits test normal, replace the MGU.
  5. Reconnect the MGU X2 connector and disconnect the SGCM X2 connector. Refer to Generator with Starter Replacement  and Generator Control Module Replacement .
  6. Test the circuits in the SGCM to MGU Specification Table as indicated below.
    • If any of the circuits are not within the specified range, replace the SGCM.
SGCM to MGU Terminal Reference Table

MGU Connector/Terminal SCGM Connector/Terminal Minimum Resistance Maximum Resistance
Harness Continuity Test
B X2/7 - less than 1 ohm
C X2/6 - less than 1 ohm
D X2/4 - less than 1 ohm
E X2/17 - less than 1 ohm
F X2/20 - less than 1 ohm
G X2/19 - less than 1 ohm
H X2/5 - less than 1 ohm
MGU to SGCM Specification Table

MGU Connector/Terminal Signal Name Minimum Resistance Maximum Resistance
Measurements made to ground. SGCM disconnected and MGU connected.
D REZ- 1.6k ohms 2k ohms
H REZ+ 1.6k ohms 2k ohms
C REZ3 Over 1 M ohm -
B REZ4 Over 1 M ohm -
E REZGS (GND) - less than 5 ohm
G REZ1 Over 1 M ohm -
F X2/5 Over 1 M ohm -
SGCM to MGU Specification Table

SGCM Connector/Terminal SGCM Connector/Terminal Minimum Resistance Maximum Resistance
MGU disconnected and SGCM connected.
X2/4 X2/5 20.1 ohms 26.7 ohms
X2/6 X2/19 32.4 ohms 43.0 ohms
X2/7 X2/20 32.9 ohms 43.5 ohms
X2/4 X2/6 Over 1 M ohm -
X2/4 X2/7 Over 1 M ohm -
X2/6 X2/7 Over 1 M ohm -