Removal Procedure
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (RPO LS4) or Battery Negative Cable Disconnection and Connection (RPOs LZE/LZ4/LZ8) .
- Remove the engine sight shield. Refer to Upper Intake Manifold Sight Shield Replacement .
- Remove the drive belt. Refer to Drive Belt Replacement - Accessory .
- Disconnect the generator electrical connector (2).
- Position aside the protective boot (1) from the generator output BAT terminal for access.
- Remove the generator output BAT terminal nut (4) and remove the positive battery lead (3) from the generator.
- Remove the generator bolts and generator.