Removal Procedure
- Remove the generator. Refer to Generator Replacement (LS4) or Generator Replacement (RPOs LZE/LZ4/LZ8) .
- Remove the idle pulley. Refer to Drive Belt Idler Pulley Replacement .
- Raise and support the vehicle. Refer to Lifting and Jacking the Vehicle .
- Remove the lower tensioner bolt and rotate the tensioner to access the generator bracket bolt.
- Lower the vehicle.
- Remove the generator bracket bolts.
- Remove the generator bracket from the stud.