Installation Procedure
- Lubricate the CMP sensor O-rings with clean engine oil.
- Install the CMP sensor (1).
- Install the CMP sensor bolt (2).
Tighten: Tighten the bolt to 10 N.m (89 lb in).
- Connect the engine wiring harness electrical connector to the CMP sensor.
- Install the air cleaner inlet duct. Refer to Air Cleaner Inlet Duct Replacement .
CAUTION:
Refer to Fastener Caution
.