Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the crankshaft position (CKP) sensor.
- Ignition ON, test for 2-3 volts between the high signal circuit terminal 1 and ground.
- If less than the specified range, test the high signal circuit for an open/high resistance or for a short to ground. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the high signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Ignition ON, test for 2-3 volts between the low signal circuit terminal 2 and ground.
- If less than the specified range, test the low signal circuit for an open/high resistance or for a short to ground. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the low signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the CKP sensor.