Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the appropriate heated oxygen sensor (HO2S).
- Ignition ON, test for less than 0.1 volt between the ignition 1 voltage circuit terminal 2 and 12 volts.
- If greater than the specified range, repair the ignition 1 voltage circuit for a short to ground or an open/high resistance.
- Ignition OFF, connect a test lamp between the control circuit terminal 3 and B+.
- If test lamp illuminates, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.
- Ignition ON, test for less than 0.3 volt between the control circuit terminal 3 and ground.
- If greater than the specified range, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the HO2S.