Circuit/System Verification
Ignition On, observe the scan tool EBCM Stop Lamp parameter. The reading should be Released and change between Applied and Released when pressing and releasing the brake pedal, the stop lamps should turn on and off.
- If not within the specified value, refer to Stop Lamps Malfunction . If the circuits test normal, replace the EBCM.