Installation Procedure
- Install the generator bracket.
- Install the generator bracket bolts and nut.
Tighten: Tighten the bolts/nut to 41 N.m (30 lb ft).
- Install the drive belt tensioner. Refer to Drive Belt Tensioner Replacement .
- Install the generator. Refer to Generator Replacement (4.3L) or Generator Replacement (4.8L, 5.3L, and 6.0L) or Generator Replacement (6.6L) .
- Install the heater hose bracket bolt.
Tighten: Tighten the bolt to 25 N.m (18 lb ft).
- Install the wiring harness bracket bolt.
Tighten: Tighten the bolt to 25 N.m (18 lb ft).
- Install the cooling fan. Refer to Fan Replacement .
- Install the drive belt. Refer to Drive Belt Replacement .
- Align the hinge clip with the lip on the throttle body.
In order to install the air cleaner outlet duct, pivot the air cleaner outlet duct downward until the mounting stud is through the hole.
- Install the air cleaner adapter nut.
- Install the PCV hose.
- Tighten the air cleaner outlet duct clamp at the MAF/IAT sensor.
Tighten: Tighten the clamps to 4 N.m (35 lb in).
NOTE:
Refer to Fastener Notice
.