Installation Procedure
- Install the recirculation door (2) from the recirculation assembly (1).
- Install the recirculation actuator.
- Install the screws to the recirculation actuator (2).
Tighten: Tighten the screws to 1.9 N.m (18 lb in).
- Connect the electrical connector (3).
- Assemble the HVAC module case halves (1, 4).
- Install the screws to assemble the HVAC module case halves.
Tighten: Tighten the screws to 1.9 N.m (17 lb in).
- Install the HVAC module assembly. Refer to HVAC Module Assembly Replacement .
NOTE:
Refer to Fastener Notice
in Cautions and Notices.