LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2006 >> Optra LS, Standard >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - 1.6L (L91) >> Repair Instructions >> Heated Oxygen Sensor Replacement - Position 2 >> Installation Procedure

Installation Procedure

    Fig 1: View Of HO2S
    GM1265321Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: A special anti-seize compound is used on the oxygen sensor threads. This compound consists of a liquid graphite and glass beads. The graphite will burn away, but the glass beads will remain, making the sensor easier to remove. New or serviced sensors will already have the compound applied to the threads. If a sensor is removed from any engine and is to be reinstalled, the threads must have an anti-seize compound applied before reinstallation.
  1. Coat the threads of the HO2S2 with an anti-seize compound, if needed.
  2. NOTE: Refer to Fastener Notice in Cautions and Notices.
  3. Install the HO2S2.

    Tighten:  Tighten the heated oxygen sensor to 42 N.m (31 lb ft)  .

  4. Fig 2: Identifying HO2S 2
    GM1343728Courtesy of GENERAL MOTORS CORP.
  5. Connect the electrical connector.