  1. Ignition OFF, disconnect the harness connector of the fuel pump relay.
  2. IMPORTANT: The test lamp is used to load the circuit and may not illuminate.
  3. Connect a test lamp between the ignition 1 voltage circuit of the fuel pump relay and the negative terminal of the battery.
  4. Ignition ON, test for less than 0.1 volt between the ignition 1 voltage circuit of the fuel pump relay and the positive battery terminal.
    • If greater than 0.1 volt, repair the ignition 1 voltage circuit of the fuel pump relay for a short to ground or an open/high resistance.
  5. With the ignition OFF, connect a test lamp between the control circuit and the ignition 1 voltage circuit of the fuel pump relay.
  6. With the ignition ON, use a scan tool to command the fuel pump relay ON. The test lamp should turn ON for about 3-5 seconds and then turn OFF.
    • If the test lamp remains ON all the time, test for a short to ground on the control circuit. If circuit/connections test normal, replace the ECM.
    • If the test lamp remains OFF all the time, test for a short to voltage or an open/high resistance on the control circuit. If circuit/connections test normal, replace the ECM.
  7. If all circuits/connections test normal, test or replace the fuel pump relay.