Brake Pedal Data List
- BPPS High During Learn
-
The scan tool displays No or Yes. The scan tool displays Yes if signal is high during learn.
- BPPS Learned Home Position
-
The scan tool displays voltage. The brake pedal position sensor learned home value of 0-5 volts.
- BPPS Low During Learn
-
The scan tool displays No or Yes.
- BPPS Move During Learn
-
The scan tool displays No or Yes.
- BPP Sensor Circuit
-
The scan tool displays Inactive or Active. The commanded state of the brake pedal position sensor. When the brakes are applied the scan tool will display Active.
- BPP Sensor
-
The scan tool displays Counts. With brake applied displays 1 to 3 counts. Unapplied displays 0.
- BPP Sensor Reference
-
The scan tool displays Counts. Always displays 1 to 3 counts.
- BPPS Status
-
The scan tool displays Unlearned/Learned/Invalid/Undecided. This is the status of the brake pedal position sensor with regards to learning the home position.
- Brake Applied Output Signal
-
The scan tool displays On/OFF. When the brake is applied this parameter displays ON.
- Calculated Brake Pedal Position
-
The scan tool displays counts. when the brake is applied displays 2 counts. When the brake is not applied displays 255 counts.