Typical Scan Tool Data
CMP Sensor
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Engine Running | ||||
| 5-Volt Reference Circuit | Same as Engine Speed | 0 RPM | 0 RPM | 0 RPM |
| CMP Sensor Signal Circuit | Same as Engine Speed | 0 RPM | 0 RPM | 0 RPM |
| Low Reference Circuit | Same as Engine Speed | Same as Engine Speed | 0 RPM | 0 RPM |