Application Specification
Metric English
Cooling Type Forced Water Circulation
  • Coolant Capacity - 2.0L
7.5 liters 7.9 quarts
  • Coolant Capacity - 2.5L
8.0 liters 8.5 quarts
Electric Cooling Fan
  • Cooling Fan Type
Electric
  • Blade Number
5
  • Cooling Fan Diameter
320 mm 12.6 in
  • Temperature at Low Speed ON
96°C 204.8°F
  • Temperature at Low Speed OFF
94.5°C 202.1°F
  • Temperature at High Speed ON
99°C 210.2°F
  • Temperature at High Speed OFF
97.5°C 207.52°F
Radiator Type - 2.0L Cross-flow
Radiator Type - 2.5L Down-flow
  • Core Width
701 mm 27.60 in
  • Core Height
372 mm 14.65 in
  • Core Depth
18 mm 0.71 in
Thermostat Type Wax Expansion Pellet Type
  • Temperature - Opened Initially - 2.0L
83-87°C 181.4-188.6°F
  • Temperature - Opened Initially - 2.5L
80-84°C 144-215.2°F
  • Temperature - Perfectly Opened - 2.0L
100°C 212°F
  • Temperature - Perfectly Opened - 2.5L
97°C 206.6°F
  • Temperature - Perfectly Closed - 2.0L
78-82°C 172.4-179.6°F
  • Temperature - Perfectly Closed - 2.5L
77-81°C 170.6-177.8°F
  • Stroke - Perfectly Opened
8 mm 0.315 in
Water Pump Type Centrifugal
  • Impeller Diameter
65 mm 2.56 in
  • Impeller Blade Number
6