Installation Procedure
WARNING: This page is about a different car, the 2005 Pontiac Pursuit and 2005 Chevrolet Cobalt. However, it is still accessible from the selected car via links, so may be relevant.
- Install the surge tank.
- Connect the coolant level sensor electrical connector.
- With the surge tank raised, install the surge tank outlet hose.
- Reposition the hose clamp using J 38185 to secure the hose. See Special Tools .
- Install the surge tank nut.
Tighten: Tighten the nut to 10 N.m (89 lb in).
- Set the underhood junction block bracket into position.
- Install the underhood junction block bracket nuts (1, 2).
Tighten: Tighten the nuts to 10 N.m (88 lb in).
- Install the underhood junction block bracket bolt (3).
Tighten: Tighten the bolt to 25 N.m (18 lb ft).
- Install the surge tank inlet hose to the surge tank.
- Reposition the hose clamp using J 38185 to secure the hose. See Special Tools .
- Fill the cooling system. Refer to Draining and Filling Cooling System (2.0L - LSJ) or Draining and Filling Cooling System (2.2L - L61) .
NOTE:
Refer to Fastener Notice
in Cautions and Notices.