Conditions for Running the DTC
- The engine is running.
- The Ignition 1 Signal voltage parameter is more than 11 volts.
- The EGR valve is commanded to 0 percent for one second after the EGR valve has been commanded to open more than 40 percent for 0.5 seconds.
- The EGR command will be disabled if the startup engine coolant temperature (ECT) is less than 5°C (41°F) and will not enable until the ECT is more than 75°C (167°F).