Conditions for Running the DTC
The following conditions must be met:
- DTCs P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0442, P0443, P0446, P0449, P0452, P0453, P0455, P0496 are not set.
- DTCs P2A01, P0401 (where applicable), and P0420 are not commanding fuel.
- The system voltage is between 9-18 volts.
- The scan tool special functions are not active.
- The TP Sensor parameter is between 4-40 percent.
- The ECT Sensor parameter is less than 131°C (268°F).
- The Air Fuel Ratio parameter is between 12:1 and 16.5:1.
- The Loop Status parameter is closed.
- All fuel injectors are ON.
- The traction control is not active.
- The above conditions have been met for at least 3 seconds.