LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2005 >> Optra5 Base, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC Systems - Automatic >> Repair Instructions >> Recirculation Actuator Replacement >> Installation Procedure

Installation Procedure

    Fig 1: View Of Recirculation Actuator Electrical Connector
    GM1308436Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice in Cautions and Notices.
  1. Install the motor with the retaining screws.
  2. Install the actuating rod.
  3. Connect the electrical connector.
  4. Install the bracket mounting high-blower relay with a screw.
  5. Remove the glove box. Refer to Storage Compartment Replacement - Instrument Panel (I/P) in Instrument Panel, Gages and Console.
  6. Connect the negative battery cable.