Installation Procedure
- Install the blower motor and the seal with the shock mount pads in the heater/air distributor case. Hold the blower motor in position.
- Install the screws to secure the blower motor to the heater/air distributor case.
Tighten: Tighten the blower motor retaining screws to 1.2 N.m (11 lb in) .
- Connect the blower motor electrical connector and resistor connector.
- Connect the negative battery cable.
- Confirm that the blower motor operates properly.
- Replace the glove box. Refer to Instrument Panel Storage Compartment Replacement in Instrument Panel, Gauges and Console.