Open Loop

When the engine is first started and it is above 400 RPM, the system goes into Open Loop operation. In Open Loop, the engine control module (ECM) ignores the signal from the heated oxygen sensor (HO2S) and calculates the air/fuel ratio based on inputs from the engine coolant temperature (ECT) sensor and the manifold absolute pressure (MAP) sensor. The sensor stays in Open Loop until the following conditions are met: