LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2003 >> Tracker 2D Utility, RWD, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> System Tests >> Test C: Charge Indicator Light Inoperative

Test C: Charge Indicator Light Inoperative

  1. Check generator mounting. Check wiring harness electrical connections at generator. Check battery cables. Check drive belt tension. Ensure battery is fully charged. See BATTERY TESTING & INSPECTION  under ON-VEHICLE TESTING. Reviewing the description and operation information will help determine the correct symptom diagnostic procedure when a malfunction exists and will also help determine if the condition described by the customer is normal operation. See DESCRIPTION & OPERATION  . If review was performed, go to next step.
  2. Turn ignition switch to RUN position. If battery charge indicator light illuminates during 5-second bulb check, problem is intermittent. Check wiring and connections. If battery charge indicator light does not illuminate during 5-second bulb check, go to next step.
  3. Turn ignition switch to LOCK position. Disconnect generator harness connector. Connect a 20-amp fused jumper wire between ground and White/Red wire at generator harness connector. Turn ignition switch to RUN position. If battery charge indicator lamp does not illuminate, go to step  6 . If battery charge indicator lamp illuminates, go to next step.
  4. Check for an open in Black/White wire between generator and junction box. See COMPONENT LOCATIONS  and WIRING DIAGRAMS  . If problem exists, repair as necessary and go to step  9 . If problem does not exist, go to next step.
  5. Replace generator. See GENERATOR  under REMOVAL & INSTALLATION. After repair, go to step  9 .
  6. Inspect charge indicator bulb. Check for an open in Black/White wire between junction box and instrument cluster. See WIRING DIAGRAMS  . If problem exists, repair as necessary and go to step  9 . If problem does not exist, go to next step.
  7. Check for an open in White/Red wire between instrument cluster and generator. See WIRING DIAGRAMS  . If problem exists, repair as necessary and go to step  9 . If problem does not exist, go to next step.
  8. Repair or replace instrument cluster printed circuit. See appropriate ANALOG INSTRUMENT PANELS article in ACCESSORIES & EQUIPMENT. After repairs, go to next step.
  9. Operate system to verify repair. If condition was found and corrected, system is okay. If condition was not found, go to step  2 .