Test Description
The number below refers to the step number on the diagnostic table.
- 3: This step checks the keyless entry serial data circuit for voltage supplied by the BCM.
DTC B3102
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| Schematic Reference: Keyless Entry Schematics | ||||
| 1 | Did you perform the Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - Remote Keyless Entry |
| 2 |
|
- | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
| 3 |
|
B+ | Go to Step 5 | Go to Step 4 |
| 4 | Test the keyless entry serial data circuit for a short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 9 | Go to Step 6 |
| 5 | Inspect for poor connections at the harness connector of the RCDLR. Refer to Testing for Intermittent Conditions and Poor Connections
andConnector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 9 | Go to Step 7 |
| 6 | Inspect for poor connections at the harness connector of the body control module (BCM). Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 9 | Go to Step 8 |
| 7 |
IMPORTANT:
Perform the keyless entry transmitter programming procedure when replacing the RCDLR. Replace the RCDLR.Did you complete the replacement? |
- | Go to Step 9 | - |
| 8 |
IMPORTANT:
Perform the BCM programming procedure when replacing the BCM. Did you complete the replacement?Replace the BCM. Refer to Body Control Module Replacement in Body Control System. |
- | Go to Step 9 | - |
| 9 |
|
- | Go to Step 2 | System OK |