Test Description
The numbers below refer to the step numbers in the diagnostic procedures.
- 2
This step verifies that a failure condition is active. - 4
Introducing smoke in 15 second intervals may allow smaller leak areas to be more noticeable. When the system is less pressurized, the smoke will sometimes escape in a more condensed manner. - 6
This step verifies proper operation of the FTP sensor. - 7
A normal operating FTP sensor should increase above 5 in. of H2O and Stop between 6 inches of H2O and 7 in. of H2O. - 9
This step tests the EVAP purge valve vacuum source between the EVAP purge valve and the Intake manifold for restrictions or blockages.