Installation Procedure
- Connect the horn ground lead (2) into the lower left threaded hole in the steering wheel.
- Connect the horn contact lead into the steering column cam tower.
- Rotate the horn contact turn 1/4 turn clockwise to lock.
- Connect the inflator module electrical connector and CPA (4).
Important:
Route the driver inflator wires, the redundant control wires, and the horn wires correctly.
- Align the driver inflator module fasteners to the steering column fastener holes.
- Push the driver inflator module firmly into the steering column in order to engage the fasteners.
- Enable the SIR system. Refer to Enabling the SIR System .