Keyless Entry System Inoperative
Keyless Entry System Inoperative
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: POWER DOOR LOCKS DEFINITION: This table diagnoses the power door locks are operative using the power door lock switches and inoperative using the remote keyless entry. |
|||
| 1 | Did you review the Keyless Entry System Description and Operation and perform the necessary inspections? | Go to Step 2 | Go to Symptoms - Keyless Entry |
| 2 | Verify that the power doors work from the power door switches and not from the Remote Keyless Entry Fob. Does the RKE Fob operate the door locks? |
Go to TESTING FOR INTERMITTENT AND POOR CONNECTIONS | Go to Step 3 |
| 3 |
|
Go to Step 6 | Go to Step 4 |
| 4 |
|
Go to Step 5 | Go to Step 7 |
| 5 | Repair the open or short to ground condition in the PNK/WHT wire between cavity L of the remote control door lock receiver and cavity 8 of the data link connector (DLC). Did you complete the repair? |
Go to Step 8 | - |
| 6 |
|
Go to Step 8 | - |
| 7 | Replace the remote control door lock receiver. Refer to Remote Control Door Lock Receiver Replacement
. Is the replacement complete? |
Go to Step 8 | - |
| 8 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |