Code Enable Criteria
For DTC to run, the following conditions must be met:
- DTCs P0112, P0113, P0117, P0118, P0125, P1111, P1112, P1114, or P1115 are not set.
- Minimum air temperature is 19°F (-7°C) or more.
- Start-up coolant temperature is less than 104°F (40°C) on M/T models and 154°F (68°C) on A/T models.
- Region 1 - Air temperature is more than 50°F (10°C) and the start-up coolant temperature is more than 50°F (10°C).
- Region 2 - Air temperature is more than 19°F (-7°C) and the start-up coolant temperature is between 19°F (-7°C) and 50°F (10°C).
- Region 3 - Air temperature is more than 19°F (-7°C) and the start-up coolant temperature is between -40°F (-40°C) and 19°F (-7°C).
DTC will set when:
Region 1- On A/T models, engine run time is more than 139 seconds to achieve a closed loop temperature of 68°F (20°C). Calibrated minimum amount of airflow has been exceeded. Maximum idle time has been less than 104 seconds. On M/T models, engine run time is more than 325 seconds to achieve a closed loop temperature of 104°F (40°C). Calibrated minimum amount of airflow has been exceeded. Maximum idle time has been less than 250 seconds.
Region 2- On A/T models, engine run time is more than 251 seconds to achieve closed loop temperature of 68°F (20°C). Calibrated minimum amount of airflow has been exceeded. Maximum idle time has been less than 188 seconds. On M/T models, engine run time is more than 400 seconds to achieve closed loop temperature of 104°F (40°C). Calibrated minimum amount of airflow has been exceeded. Maximum idle time has been less than 300 seconds.
Region 3- On A/T models, engine run time is more than 324 seconds to achieve closed loop temperature of 68°F (20°C). Calibrated minimum amount of airflow has been exceeded. Maximum idle time has been less than 243 seconds. On M/T models, engine run time is more than 475 seconds to achieve closed loop temperature of 104°F (40°C). Calibrated minimum amount of airflow has been exceeded. Maximum idle time has been less than 375 seconds.