Right Power Mirror Inoperative
- If power mirrors system check was not performed, go to SYSTEM OPERATION CHECK under TROUBLE SHOOTING. If power mirrors system check was performed, go to next step.
- If right mirror does not move in any direction, go to step 12 . If right mirror moves in any direction, go to next step.
- If right mirror moves left and right, go to next step. If right mirror does not move left and right, go to step 9 .
- Disconnect right outside mirror connector. Using a test light connected to ground, probe mirror connector terminal No. 3 (Red/Green wire). See Figure . Activate right mirror switch to up position. If test light comes on, go to next step. If test light does not come on, go to step 6 .
- Replace right outside power mirror. See POWER MIRROR ASSEMBLY under REMOVAL & INSTALLATION.
- Check Red/Green wire for an open between right outside mirror connector terminal No. 3 and power mirror switch connector terminal No. 7. See Figure . See WIRING DIAGRAMS . If circuit is okay, go to next step. If circuit is not okay, go to step 8 .
- Replace power mirror switch. See POWER MIRROR SWITCH under REMOVAL & INSTALLATION.
- Repair open in Red/Green wire between right outside mirror connector terminal No. 3 and power mirror switch connector terminal No. 7. Recheck system operation.
- Disconnect right outside mirror connector. Using a test light connected to ground, probe mirror connector terminal No. 1 (Red wire). See Figure . Activate right mirror switch to left position. If test light comes on, go to step 5 . If test light does not come on, go to next step.
- Check Red wire for an open between left outside mirror connector terminal No. 1 and power mirror switch connector terminal No. 8. See Figure . See WIRING DIAGRAMS . If circuit is okay, go to step 7 . If circuit is not okay, go to next step.
- Repair open in Red wire between left outside mirror connector terminal No. 1 and power mirror switch connector terminal No. 8. Recheck system operation.
- Disconnect left outside mirror connector. Using a test light connected to ground, probe mirror connector terminal No. 2 (Brown/Red wire). See Figure . Activate right mirror switch to down position. If test light comes on, go to step 5 . If test light does not come on, go to next step.
- Check Brown/Red wire for an open between right outside mirror connector terminal No. 2 and power mirror switch connector terminal No. 6. See WIRING DIAGRAMS . If circuit is okay, go to step 7 . If circuit is not okay, go to next step.
- Repair open in Brown/Red wire between right outside mirror connector terminal No. 2 and power mirror switch connector terminal No. 6. Recheck system operation.