Test F: Keyless Entry System Inoperative
- Test transmitter operation. See TRANSMITTER TEST under COMPONENT TESTS. Go to next step.
- Disconnect Remote Control Door Lock Receiver (RCDLR). Connect test light between RCDLR connector terminal "E" (Orange wire) and ground. See Figure . If test light is on, go to next step. If test light is off, go to step 4 .
- Connect test light between RCDLR connector terminal "F" (Orange wire) and ground. See Figure . If test light is on, go to step 5 . If test light is off, go to step 6 .
- Repair open in Orange wire between RCDLR and splice S228. Go to step 9 .
- Using DVOM, check continuity between RCDLR connector terminal "N" (Black wire) and ground. See Figure . If continuity does not exist, go to step 7 . If continuity exists, go to step 8 .
- Repair open in Orange wire between RCDLR and splice S228. Go to step 9 .
- Repair open in Black wire between RCDLR and splice S206. Go to step 9 .
- Replace RCDLR. See REMOTE CONTROL DOOR LOCK RECEIVER under REMOVAL & INSTALLATION. Reprogram replacement RCDLR to transmitter(s). See PROGRAMMING . Go to next step.
- Operate system to verify repair.