Brushes & Springs
- Using ohmmeter, check continuity between positive and negative brush holders. Continuity should not exist. If continuity exists, replace shorted brush holder assembly.
- Measure brush length. Brush length should be .45-.67" (11.5-17.0 mm). Check brush springs for corrosion or damage. Ensure spring tension is within specification. See STARTER SPECIFICATIONS table. Ensure brushes move freely in holders.