Both Power Mirrors Inoperative
- Disconnect power mirror switch harness connector. Connect test light between power mirror switch harness connector terminal "H" (Orange wire) and ground. If test light illuminates, go to next step. If test light does not illuminate, repair open in Orange wire between power mirror switch and fuse block.
- Connect test light between power mirror switch harness connector terminals "H" (Orange wire) and "A" (Black wire). If test light does not illuminate, repair open in Black wire between power mirror switch and convenience center. If test light illuminates, replace power mirror switch.