Both Power Mirrors Do Not Operate
- Disconnect power mirror switch connector. Using DVOM, check for voltage between power mirror switch harness connector terminal "E" (Orange wire) and ground. If test light glows, go to next step. If test light does not glow, repair open in Orange wire between power mirror switch and fuse block.
- Connect DVOM between power mirror switch harness connector terminals "D" (Black wire) and ground. If test light glows, check for poor connection at power mirror switch connector. If connection is okay, replace switch. If test light does not glow, repair poor connection or open in Black wire to power mirror switch.