Left Mirror Does Not Operate In Up/Down Or Left/Right Mode
- Ensure power mirror switch connector C1 (Black) is connected. Disconnect power mirror switch connector C2. Connect test light between connector C2 terminals "A" (Light Green wire) and "C" (Yellow wire). With left mirror selected, move power mirror switch to up, then down positions. If test light glows in both positions, go to next step. If test light does not glow in both positions, replace power mirror switch.
- Connect test light between connector C2 terminals "A" (Light Green wire) and "B" (White wire). Move power mirror switch to right, then left positions. If test light glows in both positions, replace left power mirror drive unit. If test light does not glow in both positions, replace power mirror switch.